From monitoring and controlling standby/load management to multi-unit utility paralleling installations, whether you’re on- or off-site, our switchgear is engineered to manage your power system. Automatic Transfer Switches, range from 30A to 5000A and are designed to seamlessly redirect power between your main and backup sources. It’s control for continuous power and continued safety.

The benefit of Caterpillar’s vast experience in power generation is fully realized in its generator switchgear offering. Available from 600V through 15 kV, Cat® switchgear provides a harmonized system solution by being able to integrate all elements of monitoring and control of a Cat® generator set in a single-source package. For integration of Cat generator sets into a customer’s facility, Caterpillar offers switchgear suitable for applications ranging from single standby/load management to multi-unit utility paralleling installations. In any of these cases, Cat switchgear can offer remote communication capabilities for monitoring and control of your total system. Cat switchgear employs a feature rich microprocessor based control system that is combined with an easy to use touchscreen operator interface panel. The entire system can be controlled from the switchgear-mounted touchscreen, or it can be controlled/monitored from a remote site through a personal computer. Caterpillar offers three standard switchgear products that can support a wide variety of applications or can provide a custom designed system to meet your specific site’s needs as required. Our XLM series products supports transfer between the utility source and generator bus, as well as affording capability for parallel operation with the utility for load management applications. The EGP series supports paralleling on an isolated generator bus and is commonly used in prime power or emergency standby systems. Finally, our LM series supports single unit paralleling with utility for load management and peak shaving applications. Contact your local Cat dealer for additional product information.

Showing all 6 results

Cat Customizable Switchgear and Controls

Switchgear and Paralleling Controls

Configuration

Application-specific switchgear with control logic designed to meet any customer's sequence of operations. Examples are 3+ Utilities, CHP applications, complex load shed schemes, etc

Modes of Operation

All modes of paralleling generator sets to each other and to other sources (utility, alternative fuels, wind, etc) can be supported. Caterpillar generation and control experts can design and program the most complex power schemes to meet your critical power needs

Application

LV and MV ( 208V - 38 kV) 50 / 60 Hz

Read More

Cat EGP Switchgear

Switchgear and Paralleling Controls

Configuration

Configurable PLC based switchgear capable of controlling and monitoring multiple generator sets, tie and load breakers in conjunction with downstream transfer switches for standby or emergency applications

Modes of Operation

Multi-unit Island and multi-unit standby mode with optional redundant controls and components.

Application

LV and MV (208V - 38 kV)

Read More

Cat EGP Switchgear

Switchgear and Paralleling Controls

Configuration

Remote monitoring and control for up to 8 generator sets via high-speed network. Enables paralleling a group of EMCP 4.4 equipped generator sets to a single utility source.

Modes of Operation

Emergency standby, island, utility paralleling

Application

LV and MV (208V - 38 kV)

Read More

Cat Switchgear

Switchgear and Paralleling Controls

Configuration

IP4X

Operating Temperature

35 u00b0C / 40 u00b0C @ 1 hr, option for 0u202650 u00b0C (32u2026122 u00b0F)

Standard Widths

600 mm for ABB Emax2 E2 1600 - 2500A. 750 mm for ABB Emax2 E4 3200 - 4000A. 1200 mm for ABB Emax2 E6 4000 - 6300A.

Read More

Cat XLM Switchgear

Switchgear and Paralleling Controls

Configuration

Configurable PLC based switchgear capable of controlling and monitoring multiple generator sets, tie, utility and load breakers for utility paralleling applications

Modes of Operation

Emergency Standby, Utility Import/Export, Peak shaving, and base load operations with redundant controls and components. Closed transition to/from generator power

Application

LV and MV ( 208V - 38 kV

Read More

Engine Paralleling and Integration Control (EPIC)

Switchgear and Paralleling Controls

Configuration

Remote modular paralleling control system (Master Control Panel for the first 2 generator sets and optional tie breaker, separate add-on control panels for up to 8 additional generator sets, utility paralleling control, and distribution control)

Modes of Operation

Emergency Standby with redundant master control, Utility paralleling, peak shaving, and closed transition to/from Generator Power (with optional utility control panel)

Application

LV and MV (208V-27kV)

Read More