Enquire about "DE200 GC Generator Set (50 Hz)" Now
DE200 GC Generator Set (50 Hz)
Cat Generator Set Package
- Cat generator set packages have been fully prototype tested
- Accepts 100% block load in one step and meets NFPA 110 loading requirements
- Conform to ISO 8528-5 steady state and transient response requirements
Cat Diesel Engine
- Reliable, rugged, durable design
- Field-proven in thousands of applications worldwide
- Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight
A-Frame Alternator
- Superior motor starting capability minimizes need for oversizing alternator
- Designed to match performance and output characteristics of Cat diesel engines
- Robust Class H insulation
GCCP 1.1 Control Panel
- User-friendly interface and navigation
- Scalable system to meet a wide range of installation requirement
- Expansion modules and site-specific programming for specific customer requirements
Cooling System
- Designed to operate in standard ambient temperatures up to 55°C (131°F)
- Contact your Cat Dealer for specific ambient and altitude capabilities
Certifications
- CE Certification Available
- CIS Certification Available
One Safe Source
- Components used in the generator set are selected based on seamless design integration to provide the optimum performance
- The generator set is fully assembled at a Caterpillar facility following our quality guidelines
- Each generator set package is tested before leaving the Caterpillar facility
- Cat product support, including dealer service, parts and warranty covers the entire Cat power system
World Wide Product Support
- Cat dealers have over 1,800 dealer branch stores operating in 200 countries
- Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements
Generator Set Specifications | |
---|---|
Maximum Rating | 200 kVA |
Minimum Rating | 200 kVA |
Emissions/Fuel Strategy | Non Regulated |
Voltage | 380 to 415 Volts |
Frequency | 50 Hz |
Speed | 1500 rpm |
Duty Cycle | Standby |
Engine Specifications | |
---|---|
Engine Model | C7.1 I-6, 4-Cycle Diesel |
Bore | 105 mm (4.1 in) |
Stroke | 135 mm (5.3 in) |
Displacement | 7 l (427.8 inu00b3) |
Compression Ratio | 16.0:1 |
Aspiration | Turbocharged Air To Air Charge Cooled |
Fuel System | Inline |
Governor Type | Mechanical |
Generator Set Dimensions | |
---|---|
Length - Maximum | 3325 mm (130.9 in) |
Width - Maximum | 1134 mm (44.6 in) |
Height - Maximum | 1666 mm (65.6 in) |
Dry Weight - Genset (maximum) | 1931 kg (4257 lb) |
Standard Equipment
- Engine
- C7.1, Inline 6 Cylinder, 4 Stroke Diesel
- Control Panels
- GCCP 1.1
- Enclosure
- Cat GC Enclosure
- Fuel Storage
- Single Wall 8 Hour Tank
- Alternator
- A Frame Standard Alternator
- Governor
- Mechanical Governor
- Air, Cooling & Exhaust
- Enclosure Silencer
- General
- Engine and alternator pre-paint, Caterpillar Yellow
Optional Equipment
- Auxiliary Supply Voltage
- 120V
- Certification
- Certificate of Conformance
- Australia, CIS, Gulf Certification
- Alternator Requirements
- Space Heater
- Fuel Storage
- Dual Wall 8 Hour Tank
- Single Wall Tank With Containment
- Low Fuel Level Alarm
- Low Fuel Level Shutdown
- High Fuel Level Alarm
- Genset Control
- Panel Mounted Audible Alarm
- Volt Free Contacts for Genset Running
- Volt Free Contacts for Common Alarm
- Battery Charger
- Earth Leakage
- USB to RS485 Communications Device
- Emergency Stop with Key
- Earth Fault
- Coolant Heater
- Low Coolant Level Shutdown
- Battery
- Standby Pack (Smart Jacket Water Heater, Battery Charger)
- Circuit Breaker
- 4 Pole Circuit Breaker 200A
- 4 Pole Circuit Breaker 250A
- 3 Pole Circuit Breaker 630A
- 3 Pole Circuit Breaker 200A
- 3 Pole Circuit Breaker 250A
- 4 Pole Circuit Breaker 400A
- 4 Pole Circuit Breaker 630A
- Circuit Breaker Padlock
- Neutral Earth Link
- Overload via Alarm Switch on Breaker
- 3 Pole Circuit Breaker 400A
- Testing & Packaging
- PGS Test Report @ 1.0PF
- PGS Test Report @ 0.8PF