Generator Set Specifications | |
---|---|
Maximum Rating | 600 ekW |
Minimum Rating | 600 ekW |
Emissions/Fuel Strategy | EPA Stationary Emergency |
Voltage | 480 to 600 Volts |
Frequency | 60 Hz |
Speed | 1800 rpm |
Duty Cycle | Standby |
Engine Specifications | |
---|---|
Engine Model | Cat® C18 In-line 6, 4-cycle Diesel |
Bore | 145 mm (5.7 in) |
Stroke | 183 mm (7.2 in) |
Displacement | 18.1 l (1106 inu00b3) |
Compression Ratio | 14.5:1 |
Aspiration | Turbocharged Air-to-Air Aftercooled |
Fuel System | MEUI |
Governor Type | ADEMA4 |
Generator Set Dimensions | |
---|---|
Length - Maximum | 4980 mm (196.1 in) |
Width - Maximum | 1865 mm (73.4 in) |
Height - Minimum | 2009 mm (79.1 in) |
Height - Maximum | 2563 mm (100.9 in) |
Dry Weight - Genset (minimum) | 4064 kg (8959.6 lb) |
Dry Weight - Genset (maximum) | 5283 kg (11647 lb) |
Standard Equipment
- Air Inlet System
- Turbocharger
- Air cleaner – Non canister, disposable
- Aftercooler core
- Control Panel
- GCCP 1.2
- Cooling System
- Radiator sight gauge
- Thermostats and housing
- Coolant drain valve
- Jacket water pump, gear driven, centrifugal
- Blower fan and fan drive with guards
- Radiator, package mounted
- Exhaust System
- Exhaust manifold – dry
- Fuel System
- Fuel cooler
- Primary fuel filter w/integral water separator and secondary filter, spin on
- Integral tank base, 24 hours, UL142
- Engine fuel transfer pump
- Fuel priming pump
- Generator Set
- Complete system designed & built at ISO 9001:2000 certified facilities
- Factory tested to design specifications at full load conditions
- All protective devices and control functions simulated and checked
- Generators and Generator Attachments
- 6 Leads
- Voltage regulator (single phase sensing)
- Easy access to AVR and terminals
- Insulation system, Class H
- Brushless, self-excited 2/3 pitch (600V uses Internal excitation (IE))
- Terminal box, IP22 RHS facing, bottom cable entry
- Standard winding protection for non-harsh environments with relative humidity ? 95%
- IP23 Protection
- Governing System
- Cat electronic governor (ADEM A4)
- Lube System
- Oil filler and dipstick
- Shallow oil pan
- Oil filter, spin on
- Oil cooler
- Lubricating oil, CK-4 (10W-30)
- Oil drain with valve
- Fumes disposal to front of radiator
- Mounting System
- Includes lifting provisions and termination points for coolant and lube oil drain lines
- Captive linear vibration isolators between base and engine-generator
- Protection
- Safety shutoff – High water temperature
- Safety shutoff – Overspeed
- Safety shutoff – Low oil pressure
- Starting/Charging System
- 24V, 45 Amp Charging alternator
- 24-volt electric starting motor
- General
- Parts book
- Vibration damper
- Lifting eyes
Optional Equipment
- Air Inlet System
- Air cleaner (Non canister disposable)
- Bases, Mounting & Fuel Tanks
- Audio & visual fuel alarm (@90% fuel level)
- Integral tank base, 24 hours, UL142
- 5 Gallon Spill Containment
- Overfill prevention valve
- Fuel tank pill pipe & lockable cap
- Wide Base – Skid
- Circuit breaker
- 400A LSI
- Auxiliary contacts
- 400A LS/I
- 800A LSI
- 600A LSI
- 1200A LS/I
- 800A LS/I
- 600A LS/I
- 1200A LSI
- Control System
- 20A GFCI (Ground Fault Circuit Interrupter)
- Ground fault relay
- 16 -light NFPA 99/110 Annunciator
- Volt free contacts
- Twist release, Red button emergency stop
- 100A Load center
- Product link remote monitoring hardware
- Audible alarm Gp
- Earth (Ground) fault relay
- Volt free contact
- Remote E-Stop button
- Discrete I/O module
- Annunciators box
- Local annunciator
- Exhaust System
- 8″ Muffler – 25 dBA attenuation
- Flexible exhaust connection
- Manifold and turbocharger guards
- Generator
- Space heater
- Permanent magnet excitation (PMG) generator
- Starting System
- Jacket water heater
- Standard battery set: 1000 CCA, 90 amp/hr.
- Battery charger (UL Certified)
- Oversize battery set, 1400 CCA, 200 amp/hr
- General
- Extended Service Coverage
- Generator test report
- CSA Certification
- UL2200 Certification
- Tool set
- Circuit breakers
- Single LSI motorised circuit breaker
- Single LSI motorised circuit breaker
- Auxiliary contacts
- Neutral bar (208V)
- Enclosures
- E-Stop
- Sound attenuated Level 2 enclosure (White)
- AC & DC Source lights
- Sound attenuated enclosure
- Cooling System
- Coolant heater
- Stone guards
- Jacket water heater with pump
- Base / Fuel Tank
- Audio & visual fuel alarm
- Fuel System
- Integral 8 hour tank base
- Starting and Charging
- Oversize battery set
- Standard battery set
- 5 Amp Battery charger
- Battery disconnect switch
- Certifications
- CSA 22.2
- UL2200 Listed
- Seismic
- Lube System
- Manual sump pump