D60 GC Generator Set
Cat Generator Set Package
- Cat generator set packages have been fully prototype tested
- Accepts 100% block load in one step and meets NFPA 110 loading requirements
- Conform to ISO 8528-5 steady state and transient response requirements
Cat Diesel Engine
- Reliable, rugged, durable design
- Field-proven in thousands of applications worldwide
- Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight
M-Frame Alternator
- Superior motor starting capability minimizes need for oversizing alternator
- Designed to match performance and output characteristics of Cat diesel engines
- Robust Class H insulation
GCCP 1.2 Control Panel
- User-friendly interface and navigation
- Scalable system to meet a wide range of installation requirement
- Expansion modules and site-specific programming for specific customer requirements
Cooling System
- Designed to operate in standard ambient temperatures up to 55°C (131°F)
- Contact your Cat Dealer for specific ambient and altitude capabilities
Certifications
- UL 2200 Listed
- ULC Certification Available
One Safe Source
- Components used in the generator set are selected based on seamless design integration to provide the optimum performance
- The generator set is fully assembled at a Caterpillar facility following our quality guidelines
- Each generator set package is tested before leaving the Caterpillar facility
- Cat product support, including dealer service, parts and warranty covers the entire Cat power system
Worldwide Product Support
- Cat dealers have over 1,800 dealer branch stores operating in 200 countries
- Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements
Generator Set Specifications | |
---|---|
Maximum Rating | 60 ekW |
Minimum Rating | 60 ekW |
Emissions/Fuel Strategy | U.S. EPA Cert., Tier 3 |
Voltage | 208 to 600 Volts |
Frequency | 60 Hz |
Speed | 1800 rpm |
Duty Cycle | Standby |
Engine Specifications | |
---|---|
Engine Model | C4.4, In-line 4, 4-cycle diesel |
Bore | 105 mm (4.1 in) |
Stroke | 127 mm (5 in) |
Displacement | 4.4 l (269 in) |
Compression Ratio | 16.7:1 |
Aspiration | Turbocharged |
Fuel System | Electronic (adjustable) |
Governor Type | Mechanical, ADEMA4 |
Generator Set Dimensions | |
---|---|
Length - Maximum | 1962 mm (77.2 in) |
Width - Maximum | 1100 mm (43.3 in) |
Height - Maximum | 1220 mm (48 in) |
Dry Weight - Genset (maximum) | 932 kg (2054 lb) |
Standard Equipment
- Certificates
- IBC seismic and wind Certifications
- Air Inlet System
- Air cleaner
- Cartridge type air filter
- Circuit breakers
- Breakers (100% UL rated)
- 3-Pole 100% rated
- Second circuit breaker box
- Power terminal strip
- Charging System
- NFPA battery charger UL10A 120VAC
- Control Panel
- GCCP 1.2 Control panel
- Exhaust System
- Stub pipe, gaskets, raincap and SAE exhaust flange for customer use – shipped loose
- Fuel System
- Standard open set fuel tank/base supplied base, formed steel with single wall integral 24-hour fuel tank
- Control Panels
- WSS1 Low coolant level shut down
- FSS Low fuel level alarm & indication panel circuitry required when sub-base tank is selected
- NFPA110 bundle includes:
- WCA1 Low coolant temperature alarm
- A Coolant heater, remote annunciator or 0.8 power factor test may be required depending on the application
- PBC10NU NFPA battery charger
- Oil temperature gauge and sender
- PAA1 Panel mounted audible alarm
- Ground fault relay
- Remote E-stop button
- Remote annunciator module
- Audible alarm
- Volt free contacts genset run and common alarm
- Discrete I/O module
- Overload shutdown via breaker
- Low coolant temperature alarm
- Protective devices:
- Fuel level reading
- Low coolant level shutdown
- Cooling System
- Coolant drain line with valve
- Fan drive, battery charging alternator drive
- Caterpillar extended life coolant
- Radiator and cooling fan with guards
- Radiator stone guard
- Generator
- 12 Leads
- Governing System
- Mechanical and electrical governing system – model dependent
- Lube System
- Oil drain line with valve
- Lubricating oil
- General
- Engine and alternator pre-paint, Caterpillar yellow
- Starting/Charging System
- Batteries
- 24V battery with rack and cables
Optional Equipment
- Certificates
- IBC seismic and wind Certifications
- Alternator System
- R Frame auxilliary winding
- Air Inlet System
- Cartridge type air filter
- Charging System
- NFPA battery charger UL10A 120VAC
- Circuit breakers
- Breakers (100% UL rated)
- 3-Pole 100% rated
- Second circuit breaker box
- Power terminal strip
- Control Panels
- NFPA110 bundle includes: FSS Low fuel level alarm & indication panel circuitry required
when sub-base tank is selected – WSS1 Low coolant level shut down – WCA1 Low coolant temperature alarm – PAA1 Panel mounted audible alarm – PBC10NU NFPA battery charger – A Coolant heater ,remote annunciator or 0.8 power factor test may be required depending on the application - Ground fault relay
- Remote E-stop button
- Volt free contacts genset run and common alarm
- Oil temperature gauge and sender
- Audible alarm
- Remote annunciator module
- Protective devices: Low coolant temperature alarm – Low coolant level shutdown – Fuel level reading – Overload shutdown via breaker
- Discrete I/O module
- NFPA110 bundle includes: FSS Low fuel level alarm & indication panel circuitry required
- Cooling System
- Radiator transition flange
- Enclosures
- Sound attenuated enclosure, Level 1
- External emergency stop
- Sound attenuated Level 2 Enclosure (White)
- Panel viewing window
- Exhaust System
- 10, 25 and 35 dBA silencer systems
- Overhead silencer mounting kit
- Fuel System
- Emergency vent pipe
- Tank riser
- 5 Gallon spill containment
- 209 and 394 gallon sub-base fuel tanks
- 5 Gallon fill containment
- Heating Elements
- Battery heater
- Jacket water heater
- Coolant heater
- Anti-condensation heater
- Wiring for canopy space heater
- Lube oil sump heater
- Generators
- Permanent magnet excitation (PMG) generator
- Cat Alternator
- Mounting System
- Seismic vibration isolators
- Tests
- 4 Hour factory test
- Generator test report
- PGS Test report @ 0.8 power factor
- PGS Test report @ 1.0 power factor