Enquire about "CG260-16 Gas Generator Set" Now
CG260-16 Gas Generator Set
High Reliability
- Anti-knock control and cylinder balancing protect the engine from overload and ensure reliable operation
- State-of-the-art turbocharger A140 with Wastegate ensures full performance even under high temperatures and higher altitudes
- Higher reliability and lower maintenance costs due to open combustion chamber technology
High Availability, High Profitability
- Miller valve timing and optimized compression ratios ensure high efficiency and low fuels costs
- More profit for your plant
- Long maintenance intervals and general overhaul only after 80,000 oh allow an operation of 10 years without general overhaul
- Flexible fields of application also with fluctuating gas qualities due to Total Electronic Management (TEM)
Optimized Lubrication Consumption
- Savings of up to 4,000 liters of lube oil per year compared to comparable gensets<\li>
- Improved components reduce lube oil consumption<\li>
- Lower operating costs due to 30% lower lube oil consumption in comparison to similar products<\li>
Generator Set Specifications | |
---|---|
Maximum Continuous Rating | 4300 / 4000 ekW @1.0pf |
Fuel Type | Natural Gas, Biogas, Coal Gas, Associated Gas, Synthesis Gas |
Maximum Electrical Efficiency | 44.1 / 43.8% |
Maximum Standby Rating | 4500 ekW |
Frequency | 50 / 60 Hz |
RPM | 1000 / 900 rpm |
Engine Specifications | |
---|---|
Engine Model | CG260-16 |
Displacement | 271.8 l (16586 inu00b3) |
Aspiration | TA |
Bore | 260 mm (10.2 in) |
Stroke | 320 mm (12.6 in) |
Generator Set Dimensions | |
---|---|
Length | 9420 mm (371 in) |
Width | 2794 mm (110 in) |
Height | 3390 mm (133 in) |
Dry Weight - Genset | 53299.4 kg (117505 lb) |
Standard Equipment
- Air Inlet
- One-element single-stage air cleaner with enclosure and sevice indicator
- Turbocharger with a water-cooled bearing case for all cylinder
- Control Panels
- TEM (Total Electronic Management)
- Cooling
- flange connections for JW inlet and outlet
- Jacket water and SCAC thermostats
- Electrical jacket water and aftercooler coolant pump
- Exhaust
- Exhaust waste gate for the CG260-16
- Closed crankcase ventilation system
- Fuel system
- Electronic fuel metering valve
- Independently controlled cylinder monitoring and ignition system
- Pre-chamber spark plugs
- Generator
- Busbar connections
- Closed-coupled generator result in no torque transmission to the base frame
- Reactive droop
- 3-phase sensing and KVAR/PF control
- Grid code generator
- Anti-condensation space heater
- Winding temperature detectors
- Starting/Charging
- Compressed air engine start
- General
- Crankshaft vibration damper and guard
Optional Equipment
- Cooling
- CHP skid