Enquire about "CG170B-12 Gas Generator Set" Now
CG170B-12 Gas Generator Set
High Efficiency, Lower Operating Costs
- Up to 45% electrical efficiency with Natural Gas
- 43.6% electrical efficiency with biogas
- Electrical output up to 1,380 kWel
- Reduced vibration and stress on components
Compact Size, High Profitability
- Compact design that delivers up to 18% more power output at the same size as its predecessor
- Long maintenance intervals (up to 80,000 hours)
- Available in different applications, such as natural gas, biogas, wellhead
- and propane gas operation - Maximum flexibility through different engine variants
Optimized Lubrication Consumption
- Consumes ~0.15g/kWh
- Reduced lube oil temperature through better cooling performance
- Savings of up to 3,000 liters of lube oil per year compared to comparable gensets
Generator Set Specifications | |
---|---|
Continuous Rating | 1380 ekW @1.0pf |
Fuel Type | Natural Gas, Biogas, Coal Gas, Hydrogen Blend (up to 25%) |
Maximum Electrical Efficiency | 45.00% |
Maximum Standby Rating | 1380 |
Frequency | 50 Hz |
RPM | 1500 rpm |
Engine Specifications | |
---|---|
Engine Model | CG170B-12 |
Aspiration | TA |
Bore | 170 mm (6.7 in) |
Stroke | 195 mm (7.7 in) |
Generator Set Dimensions | |
---|---|
Length | 5080 mm (200 in) |
Width | 1710 mm (67 in) |
Height | 2190 mm (86 in) |
Dry Weight - Genset | 12900 kg (28440 lb) |
Standard Equipment
- Air Inlet
- One-element single-stage air cleaner with enclosure and sevice indicator
- Turbocharger with a water-cooled bearing case for all cylinder
- Control Panels
- TPEM (Total Plant & Energy Management System)
- Cooling
- Jacket water and SCAC thermostats
- ANSI/DN customer flange connections for JW inlet and outlet
- Electrical jacket water and aftercooler coolant pump
- flange connections for JW inlet and outlet
- Exhaust
- Exhaust waste gate for the CG170B-12
- PEARL/Low resistence exhaust system
- Closed crankcase ventilation system
- Fuel system
- Pre-chamber spark plugs
- Electronic fuel metering valve
- Independently controlled cylinder monitoring and ignition system
- Generator
- Reactive droop
- closed-coupled generator result in no torque transmission to the base frame
- Winding temperature detectors
- Busbar connections
- grid code generator
- Anti-condensation space heater
- 3-phase sensing and KVAR/PF control
- Starting/Charging
- 24V starting motors
- Battery disconnect switch
- General
- Crankshaft vibration damper and guard
Optional Equipment
- Cooling
- CHP skid