360°Exterior View
360°Interior View

C2.2 Generator Set

CALCULATE FINANCE

Cat Generator Set Package

  • Cat generator set packages have been fully prototype tested
  • Accepts 100% block load in one step and meets NFPA 110 loading requirements
  • Conform to ISO 8528-5 steady state and transient response requirements

Cat Diesel Engine

  • Reliable, rugged, durable design
  • Field-proven in thousands of applications worldwide
  • Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight

SR5 Alternator

  • Superior motor starting capability minimizes need for oversizing alternator
  • Designed to match performance and output characteristics of Cat diesel engines
  • Robust Class H insulation

EMCP Control Panel

  • User-friendly interface and navigation
  • Scalable system to meet a wide range of installation requirement
  • Expansion modules and site-specific programming for specific customer requirements

Cooling System

  • Designed to operate in standard ambient temperatures up to 55°C (131°F)
  • Contact your Cat Dealer for specific ambient and altitude capabilities

Certifications

Cat Dealers provide extensive post sale support including maintenance and repair agreements. Cat dealers have over 1,800 dealer branch stores operating in 200 countries. The Cat® SOSSM program cost effectively detects internal engine component condition, even the presence of unwanted fluids and combustion by-products.

One Safe Source

  • Components used in the generator set are selected based on seamless design integration to provide the optimum performance
  • The generator set is fully assembled at a Caterpillar facility following our quality guidelines
  • Each generator set package is tested before leaving the Caterpillar facility
  • Cat product support, including dealer service, parts and warranty covers the entire Cat power system

World Wide Product Support

  • Cat dealers have over 1,800 dealer branch stores operating in 200 countries
  • Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements

Generator Set Specifications
Minimum Rating 13.0 kVA
Maximum Rating 22.0 kVA
Emissions/Fuel Strategy R96/EUIIIa Equivalent
Voltage 110 to 415 Volts
Frequency 50 Hz
Speed 1500 rpm
Duty Cycle Standby, Prime
Engine Specifications
Engine Model Cat® C2.2, In-line 4, 4-cycle diesel
Bore 84 mm (3.3 in)
Stroke 100 mm (3.9 in)
Displacement 2.2 l (135.2 inu00b3)
Compression Ratio 22.5:1
Aspiration Naturally Aspirated
Fuel System Indirect Injection
Governor Type Mechanical
Generator Set Dimensions
Length - Maximum 1500 mm (59.1 in)
Width - Maximum 620 mm (24.4 in)
Height - Maximum 1115 mm (43.9 in)

Standard Equipment

  • Air Inlet System
    • Air cleaner; light duty with disposable element
    • Air cleaner; light duty with disposable element
  • Control Panel
    • EMCP 4.1
    • EMCP4.1 control panel
  • Cooling System
    • Caterpillar extended life coolant
    • Fan drive, battery charging alternator drive
    • Radiator and cooling fan with guards
    • Coolant drain line with valve
    • Radiator and cooling fan with guards
  • Exhaust System
    • Stub pipe, gaskets, raincap & SAE exhaust flange for customer use; shipped loose
    • Stub pipe, gaskets, raincap & SAE exhaust flange for customer use; shipped loose
  • Fuel System
    • Standard open set fuel tank / base supplied
    • Base, formed steel with single wall integral 8-hour fuel tank
    • Standard open set fuel tank / base supplied
    • Base, formed steel with single wall integral 8-hour fuel tank
  • Generators and Generator Attachments
    • Segregated low voltage (AC/DC) wiring panel
    • Circuit breaker, IEC, 3 pole, mounted in tower panel
    • Voltage regulator (single phase sensing)
    • Tower panel, IP22, bottom cable entry
    • 12 leads
    • IP23 Protection
    • 12 leads
    • Tower panel, IP22, bottom cable entry
    • Segregated low voltage (AC/DC) wiring panel
    • IP23 Protection
  • Governing System
    • Mechanical governing system
    • Mechancial governing system
  • Lube System
    • Oil drain line with valve
    • Lubricating oil
    • Lubricating oil
    • Oil drain line with valve
  • Mounting System
    • Captive linear vibration isolators between base and engine-generator
    • Includes lifting provisions and termination points for coolant
    • includes lifting provisions and termination points for coolant
    • Captive linear vibration isolators between base and engine-generator
  • Starting / Charging System
    • 12 Volt battery with rack and cables
    • 12V battery with rack and cables
  • General
    • Engine and alternator pre-paint, Caterpillar yellow

Optional Equipment

  • Alternator Options
    • Coastal insulation protection
  • Certificates
    • European upgrade to STD set for CE certificate
    • Global certification for CIS
  • Circuit Breakers
    • 4 Pole circuit breaker
    • Pad-locable breaker device
  • Control Panel Options
    • Battery charger
    • Volt free contacts for genset running
    • Volt free contacts for common alarm
    • EMCP 4.2
    • Emergency stop with key
  • Cooling System
    • Coolant heater
  • Enclosures
    • Sound attenuated enclosure (GALV)
    • Single point lift for enclosure
  • Fuel System
    • Low fuel level alarm
  • Mounting Options
    • Industrial silencer removal
    • Silencer installation kit
    • Battery removal
  • Special Test and Inspection
    • PGS test report @ 1.0 power factor
  • General
    • Packing Case – compact set
    • Radiator Stone Guard
    • Packing case – canopied set

Enquiry Form