Enquire about "C18 Generator Set" Now
C18 Generator Set
Cat Generator Set Package
- Cat generator set packages have been fully prototype tested
- Accepts 100% block load in one step and meets NFPA 110 loading requirements
- Conform to ISO 8528-5 steady state and transient response requirements
Cat Diesel Engine
- Reliable, rugged, durable design
- Field-proven in thousands of applications worldwide
- Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight
A-Frame Alternator
- Superior motor starting capability minimizes need for oversizing alternator
- Designed to match performance and output characteristics of Cat diesel engines
- Robust Class H insulation
GCCP1.3 Control Panel
- User-friendly interface and navigation
- Scalable system to meet a wide range of installation requirement
- Expansion modules and site-specific programming for specific customer requirements
Cooling System
- Designed to operate in standard ambient temperatures up to 55°C (131°F)
- Contact your Cat Dealer for specific ambient and altitude capabilities
Certifications
One Safe Source
- Components used in the generator set are selected based on seamless design integration to provide the optimum performance
- The generator set is fully assembled at a Caterpillar facility following our quality guidelines
- Each generator set package is tested before leaving the Caterpillar facility
- Cat product support, including dealer service, parts and warranty covers the entire Cat power system
Worldwide Product Support
- Cat dealers have over 1,800 dealer branch stores operating in 200 countries
- Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements
Generator Set Specifications | |
---|---|
Maximum Rating | 715 kVA |
Minimum Rating | 550 kVA |
Emissions/Fuel Strategy | Low Fuel, China Nonroad III Emis Stds |
Voltage | 380 to 415 Volts |
Frequency | 50 Hz |
Speed | 1500 rpm |
Duty Cycle | Standby, Prime |
Engine Specifications | |
---|---|
Engine Model | C18 ATAAC, I-6, 4-Stroke Water-Cooled Diesel |
Bore | 145 mm (5.71 in) |
Stroke | 183 mm (7.2 in) |
Displacement | 18.13 l (1106.36 inu00b3) |
Compression Ratio | 14.5:1 |
Aspiration | Air to Air Aftercooled |
Fuel System | Electronic unit injection |
Governor Type | Ademu00e2u201eu00a2A4 |
Generator Set Dimensions | |
---|---|
Length - Maximum | 4135 mm (162.4 in) |
Width - Maximum | 1989 mm (78.3 in) |
Height - Maximum | 1906 mm (75 in) |
Standard Equipment
- Air Inlet System
- Turbocharger
- Light duty air cleaner
- Aftercooler core
- Air Inlet
- Air cleaner
- Control System
- GCCP 1.2
- Exhaust
- Exhaust flange outlet
- Cooling
- Coolant drain line with valve
- Caterpillar extended life coolant
- Fan drive, battery charging alternator drive
- Radiator and cooling fan with guard
- Exhaust System
- Stainless steel exhaust flex gaskets, raincap and SAE exhaust
flange for customer use – shipped loose
- Stainless steel exhaust flex gaskets, raincap and SAE exhaust
- Fuel
- Secondary fuel filters
- Fuel priming pump
- Primary fuel filter with integral water separator
- Fuel System
- Standard 8 hour open set fuel tank
- Generator
- IP23 Protection
- Load adjustment module provides engine relief upon load impact and improves load acceptance and recovery time
- Matched to the performance and output characteristics of Cat engines
- Generator and Attachments
- Segregated low voltage (AC/DC) wiring panel
- Integrated voltage regulator (IVR)
- A Frame generator – IP21 protection
- Integrated voltage regulator (IVR)
- Mandatory option circuit breaker, IEC, 3 pole, mounted in power centre
- Power center, IP22
- Matched to the performance and output characteristics of Cat engines
- Power Termination
- Busbar
- Governing System
- Cat electronic governor (ADEM A4)
- Control Panel
- GCCP Genset Controller
- Lube System
- Lubricating oil
- Oil drain valves
- Mounting
- Rubber vibration isolators
- Mounting System
- Captive linear vibration isolators between base and engine-generator.
includes lifting provisions and termination points for coolant
and lube oil drain lines
- Captive linear vibration isolators between base and engine-generator.
- Starting/Charging
- 24 Volt battery with rack and cables
- General
- Engine and alternator pre-paint, Caterpillar yellow
Optional Equipment
- Exhaust
- Industrial, residential, critical mufflers
- Air Inlet System
- Dual element air cleaner
- Single element air cleaner
- Circuit breakers
- 3 Pole (IEC-100% rated) Circuit breakers – Motorised
- 4 Pole (IEC-100% rated) Circuit breakers – Motorised
- Circuit breaker (IEC) Auxiliary contacts
- Padlockable circuit breaker device
- 3 Pole (IEC-100% rated) Circuit breakers – Package mounted
- 4 Pole (IEC-100% rated) Circuit breakers – Package mounted
- Power terminal strip
- Shunt trip for IEC breaker
- Generator
- Anti-condensation heater
- Excitation: [ ] Permanent magnet excitation (PMG) Excited (PM) [ ] Internally Excited (IE)
- Oversize and premium generators
- Power Termination
- Circuit breakers, IEC compliant
- Circuit breakers, UL listed
- Control Panels
- Local & remote annunciator modules
- Load share module
- Remote monitoring software
- EMCP (4.2) (4.3) (4.4)
- Digital I/O module
- Control System
- Oil temperature displays
- GCCP 1.5
- Volt free contact
- Protective devices: Earth fault relay – earth leageage Ground fault relay – Overload shutdown via breaker – Low fuel level alarm – Low fuel level shutdown – High fuel level alarm – Fuel level sensor
- Local alarm modules
- Remote annunciator module
- Local alarm horn
- Cooling System
- Low coolant temperature alarm
- Radiator duct flange
- Starting/Charging
- Oversize batteries
- Jacket water heater
- Battery chargers
- Heavy duty starting system
- Charging alternator
- Enclosures
- Sound attenuated enclosures
- Exhaust System
- Manifold and turbocharger guards
- Engine mounted muffler
- 8 and 10 inch elbow kits
- 8 and 10 inch GP flanges
- 10, 25 and 35 end in / end outmufflers
- Fuel System
- Integral – Dual wall fuel tank base
- Manual fuel transfer pump
- Fuel transfer system
- Generator and Attachments
- LC frame generator
- Permanent magnet excitation (PMG)
- LC frame oversize generators
- Space heaters
- A Frame oversize generator
- A Frame CIP generator
- Ingress protection
- LC frame CIP generator
- General
- Single or dual wall integral fuel tanks
- UL 2200 package
- Enclosures: Sound attenuated, weather protective
- EU Certificate of Conformance (CE)
- Integral & sub-base UL listed dual wall fuel tanks
- Narrow, wide or skid base
- The following options are based on regional and product configuration:
- Seismic Certification per applicable building codes: IBC 2000, IBC 2003, IBC 2006, IBC 2009, CBC 2007
- EEC Declaration of Conformity
- CSA Certification
- Sound attenuated, weather protective or high ambient weather protective enclosure
- Automatic transfer switches (ATS)
- Single or dual wall sub-base fuel tanks
- Lube System
- Manual sump pump
- Starting and Charging
- Jacket water heaters
- 5 Amp Battery charger
- Battery disconnect switch