Gas Generator CG132B-16

Lower Operating Costs

Optimized engine components mean the CG132 uses up to 50 percent les lubricating oil than competing generator sets, which means more money stays in your company’s pockets.

Smaller footprint

The CG132 uses nearly 50 percent less space than similar system. Less space means lower installation costs.

System Control

Control the entire system, not just the engine, with the Cat Total Electronic Management System. Features like temperature and pressure monitoring for each cylinder and anti-knock control allow for maximum power output and the best possible fuel utilization, even if gas composition changes.

Flexible Fuel Usage

Our gas-mixer technology and Total Electronic Management System let you use a wide variety of gases, including problematic gases like digester, landfill and sewage gases

Gas Generator Sets Specification
Maximum Continuous Rating 800 kW
Fuel Type Natural Gas, Biogas
Maximum Electrical Efficiency 43.5%/42.6%
Maximum Standby Rating 800 kW
Frequency 50/60Hz
RPM 1500/1800rpm
Engine Specifications
Aspiration TA
Bore 132 mm (5.2 in)
Displacement 35 l (2135.8 inu00b3)
Engine Model CG132
Stroke 160 mm (6.3 in)
Generator Set Dimensions
Length 4200 mm (165 in)
Width 1780 mm (70 in)
Height 2150 mm (85 in)
Dry Weight - Genset NaN kg (NaN lb)

Standard Equipment

  • Air Inlet
    • One-element single-stage air cleaner with enclosure and sevice indicator
    • Turbocharger with a water-cooled bearing case for all cylinder
  • Control Panels
    • TPEM (Total Plant & Energy Management System)
  • Cooling
    • Jacket water and SCAC thermostats
    • Electrical jacket water and aftercooler coolant pump
    • flange connections for JW inlet and outlet
    • ANSI/DN customer flange connections for JW inlet and outlet
    • Flange connections for JW inlet and outlet
    • ANSI/DN customer flange connections for JW inlet and outlet
    • Cat flanges on SCAC circuit
  • Exhaust
    • Closed crankcase ventilation system
    • PEARL/Low resistence exhaust system
    • Exhaust waste gate for the CG132B-16
    • Electronic fuel metering valve
    • Pre-chamber spark plugs
  • Fuel system
    • Independently controlled cylinder monitoring and ignition system
    • Electronic fuel metering valve
    • Pre-chamber spark plugs
    • Independently controlled cylinder monitoring and ignition system
  • Generator
    • Reactive droop
    • Bus bar connections
    • Winding temperature detectors
    • Anti-condensation space heater
    • Reactive droop
    • 3-phase sensing and KVAR/PF control
    • Bus bar connections
    • Winding temperature detectors
    • closed-coupled generator result in no torque transmission to the base frame
    • Anti-condensation space heater
    • grid code generator
    • 3-phase sensing and KVAR/PF control
  • General
    • Crankshaft vibration damper and guard
  • Starting/Charging
    • 24V starting motors
    • Battery disconnect switch
    • Crankshaft vibration damper and guard
    • Battery disconnect switch

Optional Equipment

  • Air Inlet
    • Mounting stand
    • Air cleaner with precleaner
  • Cooling
    • CHP skid
    • CHP skid

Enquiry Form

REQUEST A CALL BACK