Gas Generator CG132B-16

Lower Operating Costs

Optimized engine components mean the CG132 uses up to 50 percent les lubricating oil than competing generator sets, which means more money stays in your company’s pockets.

Smaller footprint

The CG132 uses nearly 50 percent less space than similar system. Less space means lower installation costs.

System Control

Control the entire system, not just the engine, with the Cat Total Electronic Management System. Features like temperature and pressure monitoring for each cylinder and anti-knock control allow for maximum power output and the best possible fuel utilization, even if gas composition changes.

Flexible Fuel Usage

Our gas-mixer technology and Total Electronic Management System let you use a wide variety of gases, including problematic gases like digester, landfill and sewage gases

Generator Set Specifications
Natural Gas Rating 1000
Gas Generator Sets Specification
Maximum Continuous Rating 1000 kW
Fuel Type Natural Gas
Maximum Electrical Efficiency 41.0%
Frequency 50Hz
RPM 1500rpm
Engine Specifications
Aspiration TA
Bore 132 mm (5.2 in)
Displacement 35 l (2135.8 inu00b3)
Engine Model CG132B
Stroke 160 mm (6.3 in)
Generator Set Dimensions
Length 4200 mm (165 in)
Width 1780 mm (70 in)
Height 2150 mm (85 in)
Dry Weight - Genset 8070 kg (17791 lb)

Standard Equipment

  • Air Inlet
    • One-element single-stage air cleaner with enclosure and sevice indicator
    • Turbocharger with a water-cooled bearing case for all cylinder
  • Control Panels
    • TPEM (Total Plant & Energy Management System)
  • Cooling
    • Jacket water and SCAC thermostats
    • Electrical jacket water and aftercooler coolant pump
    • flange connections for JW inlet and outlet
    • ANSI/DN customer flange connections for JW inlet and outlet
    • Flange connections for JW inlet and outlet
    • ANSI/DN customer flange connections for JW inlet and outlet
    • Cat flanges on SCAC circuit
  • Exhaust
    • Closed crankcase ventilation system
    • PEARL/Low resistence exhaust system
    • Exhaust waste gate for the CG132B-16
  • Fuel system
    • Electronic fuel metering valve
    • Pre-chamber spark plugs
    • Independently controlled cylinder monitoring and ignition system
    • Electronic fuel metering valve
    • Pre-chamber spark plugs
    • Independently controlled cylinder monitoring and ignition system
  • Generator
    • Reactive droop
    • Bus bar connections
    • Winding temperature detectors
    • Anti-condensation space heater
    • Reactive droop
    • 3-phase sensing and KVAR/PF control
    • Bus bar connections
    • Winding temperature detectors
    • closed-coupled generator result in no torque transmission to the base frame
    • Anti-condensation space heater
    • grid code generator
    • 3-phase sensing and KVAR/PF control
  • Starting/Charging
    • 24V starting motors
    • Battery disconnect switch
    • Battery disconnect switch
  • General
    • Crankshaft vibration damper and guard
    • Crankshaft vibration damper and guard

Optional Equipment

  • Air Inlet
    • Mounting stand
    • Air cleaner with precleaner
  • Cooling
    • CHP skid
    • CHP skid

Enquiry Form

REQUEST A CALL BACK