Generator Set Specifications
Minimum Rating 550 ekW
Maximum Rating 600 ekW
Emissions/Fuel Strategy U.S. EPA Certified
Voltage 480 to 600 Volts
Frequency 60 Hz
Speed 1800 rpm
Duty Cycle Standby
Engine Specifications
Engine Model Cat® C18 ATAACTM In-line 6, 4-cycle diesel
Bore 145 mm (5.71 in)
Stroke 183 mm (7.2 in)
Displacement 18.1 l (1106.3 inu00b3)
Compression Ratio 14.5:1
Aspiration Air to Air Aftercooled
Fuel System Electronic unit injection
Governor Type Electronic ADEM™ A4
Generator Set Dimensions
Length - Maximum 4980 mm (196.1 in)
Width - Maximum 1865 mm (73.4 in)
Height - Maximum 2563 mm (100.9 in)

Standard Equipment

  • Air Inlet System
    • Air cleaner – Non-Canister, Disposable
    • Turbocharger
    • Aftercooler core
  • Control Panel
    • GCCP 1.2
  • Cooling System
    • Blower fan and fan drive with guards
    • Radiator, Package mounted.
    • Coolant drain valve.
    • Thermostats and housing.
    • Jacket water pump, gear driven, centrifugal
    • Radiator sight gauge
  • Exhaust System
    • Exhaust manifold; dry
  • Fuel System
    • Integral Tank Base, 24 Hrs, UL142
    • Engine fuel transfer pump
    • Fuel cooler
    • Fuel priming pump
    • Primary fuel filter w/integral water separator and secondary filter, spin on
  • Generator Set
    • All protective devices and control functions simulated and checked
    • Complete system designed & built at ISO 9001:2000 certified facilities
    • Factory tested to design specifications at full load conditions
  • Generators and Generator Attachments
    • 6 leads
    • Easy access to AVR and terminals
    • Voltage regulator (single phase sensing)
    • IP23 protection
    • Terminal Box, IP22 RHS Facing, Bottom Cable Entry
    • Standard winding protection for non-harsh environments with relative humidity ? 95%
    • Brushless, self-excited 2/3 pitch (600V uses Internal Excitation)
    • Insulation, Class H
  • Governing System
    • Cat Electronic Governor (ADEM A4)
  • Lube System
    • Shallow oil pan.
    • Fumes disposal to front of radiator.
    • Lubricating Oil, CK-4 (10W-30)
    • Oil filler and dipstick.
    • Oil cooler
    • Oil filter, spin on.
    • Oil drain with valve.
  • Mounting System
    • Includes lifting provisions and termination points for coolant and lube oil drain lines
    • Captive linear vibration isolators between base and engine-generator
  • Protection
    • Safety Shutoff – High water temperature
    • Safety Shutoff – Low Oil Pressure
    • Safety Shutoff – Overspeed
  • Starting/Charging System
    • 24-volt electric starting motor.
    • 24V,45 amp charging alternator.
  • General
    • Lifting Eyes
    • Parts Book
    • Vibration damper.

Optional Equipment

  • Air Inlet System
    • Air Cleaner (Non-Canister Disposable)
  • Bases, Mounting & Fuel Tanks
    • Integral Tank Base, 24 Hrs, UL142
    • Audio & Visual Fuel Alarm (@90% Fuel Level)
    • Overfill Prevention Valve
    • Wide Base – Skid
    • 5 gallon Spill Containment
    • Fuel Tank Fill Pipe & Lockable Cap
  • Circuit Breaker
    • 400A LSI
    • Auxiliary Contacts
    • 600A LSI
    • 1200A LSI
    • 800A LS/I
    • 1200A LS/I
    • 600A LS/I
    • 400A LS/I
    • 800A LSI
  • Exhaust System
    • 8″ Muffler – 25 dBA Attenuation
    • Manifold & Turbocharger Guards
    • Flexible Exhaust Connection
  • Generator
    • Permanent Magnet Generator
    • Space Heater
  • Starting System
    • Battery Charger (UL Certified)
    • Oversize Battery Set, 1400 CCA, 200 amp/hr.
    • Standard Battery Set: 1000 CCA, 90 amp/hr.
    • Jacket Water Heater
  • Control System
    • Product Link Remote Monitoring hardware
    • Ground Fault Relay
    • 20A GFCI (Ground Fault Circuit Interrupter)
    • Audible Alarm Gp
    • Twist Release, Red Button Emergency Stop
    • 16 -light NFPA 99/110 Annunciator
    • Volt Free Contacts
    • 100A Load Center
    • Remote E-Stop button
    • Discrete I/O module
    • Earth (Ground) fault relay
    • Volt free contact
    • Local annunciator
    • Annunciators box
  • Circuit Breakers
    • Single LSI motorised Circuit Breaker
    • Neutral bar (208V)
    • Single LSI motorised circuit breaker
    • Auxiliary contacts
  • Enclosures
    • Sound Attenuated Level 2 Enclosure (White)
    • E-Stop
    • AC & DC Source Lights
    • Sound attenuated enclosure
  • Cooling System
    • Coolant heater
    • Stone guards
    • Jacket water heater with pump
  • Base / Fuel Tank
    • Audio & visual fuel alarm
  • Fuel System
    • Integral 8 hr tank base
  • Starting and Charging
    • Battery disconnect switch
    • Standard battery set
    • 5 Amp battery charger
    • Oversize battery set
  • Certifications
    • CSA 22.2
    • UL2200 Listed
    • Seismic
  • General
    • Generator Test Report
    • CSA Certification
    • UL2200 Certification
    • Extended Service Coverage
    • Tool set
  • Lube System
    • Manual sump pump