CG170-20B Gas Generator Set

CALCULATE FINANCE

High Efficiency, Lower Operating Costs

  • Up to 45% electrical efficiency with Natural Gas
  • 43.6% electrical efficiency with biogas
  • Electrical output up to 2,300 kWel
  • Reduced vibration and stress on components

Compact Size, High Profitability

  • Compact design that delivers up to 15% more power output at the same size as its predecessor
  • Long maintenance intervals (up to 80,000 hours)
  • Available in different applications, such as natural gas, biogas, wellhead
     - and propane gas operation
  • Maximum flexibility through different engine variants

Optimized Lubrication Consumption

  • Consumes ~0.15g/kWh
  • Reduced lube oil temperature through better cooling performance
  • Savings of up to 3,000 liters of lube oil per year compared to comparable gensets

Generator Set Specifications
Continuous Rating 2300 ekW @1.0pf
Fuel Type Natural Gas, Biogas, Coal Gas, Hydrogen Blend (up to 25%)
Maximum Electrical Efficiency 45.00%
Maximum Standby Rating 2300
Frequency 50/60 Hz
RPM 1500 rpm
Engine Specifications
Engine Model CG170B-20
Aspiration TA
Bore 170 mm (6.7 in)
Stroke 195 mm (7.7 in)
Generator Set Dimensions
Length 6556 mm (258 in)
Width 1706 mm (67 in)
Height 2263 mm (89 in)
Dry Weight - Genset 21490 kg (47377 lb)

Standard Equipment

  • Air Inlet
    • One-element single-stage air cleaner with enclosure and sevice indicator
    • Turbocharger with a water-cooled bearing case for all cylinder
  • Control Panels
    • TPEM (Total Plant & Energy Management System)
  • Cooling
    • Jacket water and SCAC thermostats
    • flange connections for JW inlet and outlet
    • ANSI/DN customer flange connections for JW inlet and outlet
    • Electrical jacket water and aftercooler coolant pump
  • Exhaust
    • PEARL/Low resistence exhaust system
    • Exhaust waste gate for the CG170B-20
    • Closed crankcase ventilation system
  • Fuel system
    • Pre-chamber spark plugs
    • Electronic fuel metering valve
    • Independently controlled cylinder monitoring and ignition system
  • Generator
    • Busbar connections
    • Winding temperature detectors
    • grid code generator
    • Reactive droop
    • 3-phase sensing and KVAR/PF control
    • Anti-condensation space heater
    • closed-coupled generator result in no torque transmission to the base frame
  • Starting/Charging
    • 24V starting motors
    • Battery disconnect switch
  • General
    • Crankshaft vibration damper and guard

Optional Equipment

  • Cooling
    • CHP skid
  • Grid Code Compliance
    • 50Hz: Germany, Belgium, Great Britain, Italy, Poland, and Netherlands

Enquiry Form

    REQUEST A CALL BACK
    This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.