360°Exterior View

3516B (60 Hz) with Upgradeable Package

  • Overview
  • View product Download
CALCULATE FINANCE

Cat Generator Set Package

  • Cat generator set packages have been fully prototype tested
  • Accepts 100% block load in one step and meets NFPA 110 loading requirements
  • Conform to ISO 8528-5 steady state and transient response requirements

Cat Diesel Engine

  • Reliable, rugged, durable design
  • Field-proven in thousands of applications worldwide
  • Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight

SR5 Alternator

  • Superior motor starting capability minimizes need for oversizing alternator
  • Designed to match performance and output characteristics of Cat diesel engines
  • Robust Class H insulation

EMCP 4 Control Panel

  • User-friendly interface and navigation
  • Scalable system to meet a wide range of installation requirements
  • Expansion modules and site-specific programming for specific customer requirements

Cooling System

  • Designed to operate in standard ambient temperatures up to 50°C (122°F)
  • Contact your Cat Dealer for specific ambient and altitude capabilities

Single-Source Supplier

  • Components used in the generator set are selected at the design stage to provide optimum package performance
  • The generator set is fully assembled at a Caterpillar facility following our quality guidelines
  • Each generator set package is tested before leaving the Caterpillar facility
  • Cat product support, including dealer service, parts and warranty covers the entire Cat power system

World Wide Product Support

  • Cat dealers have over 1,800 dealer branch stores operating in 200 countries
  • Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements

Generator Set Specifications
Minimum Rating 1640 ekW
Maximum Rating 2250 ekW
Emissions/Fuel Strategy Low fuel, Low Emissions
Voltage 380 to 480 Volts
Frequency 60 Hz
Speed 1800 rpm
Duty Cycle Standby, Mission Critical, Prime, Continuous
Engine Specifications
Engine Model C32 TA, V-12, 4-Stroke Water-Cooled Diesel
Bore 145 mm (5.71 in)
Stroke 190 mm (7.48 in)
Displacement 32.17 l (1958.7 in)
Compression Ratio 15.0:1
Aspiration TA
Fuel System MEUI
Governor Type Adem™A4
Generator Set Dimensions
Length - Maximum 5957 mm (234.5 in)
Width - Maximum 2286 mm (90 in)
Height - Maximum 2494 mm (98.2 in)
Dry Weight - Genset (maximum) 13750 kg (30310 lb)

Standard Equipment

  • Air Inlet System
    • Air Cleaner; single element canister type
  • Control Panels
    • PLC functionality
    • Oil pressure (psi, kPa or bar)
    • Text alarm / event descriptions
    • KVAR/PF modes
    • Cat Connect
    • Overspeed
    • Amps (per phase & average)
    • Programmable protective relaying functions:
    • DC volts
    • EMCP 4.2B
    • Power Factor (per phase & average)
    • Reverse reactive power (kVAr) (32RV) – Overcurrent (50/51)
    • Load histogram feature
    • Generator set packages include:
    • Frequency (Hz)
    • Emergency stop pushbutton
    • Over / under voltage (27/59)
    • RFI suppression
    • 24 Volt DC operation
    • Low coolant level
    • Reverse power (kW) (32) – Reverse reactive power (kVAr) (32RV) – Overcurrent (50/51)
    • 4 Programmable relay outputs (Form A)
    • Volts (L-L & L-N)
    • Caterpillar’ s voltage regulator
    • IVR includes:
    • Auto / start / stop control
    • kVA (per phase, average & percent)
    • Lamp test
    • Over / under frequency (81 o/u)
    • Environmental sealed front face
    • 3 Phase voltage sensing
    • Engine cool
    • kVAr-hr (total)
    • Low oil pressure
    • Accessory module data link
    • Emergency stop
    • Customer data link (Modbus RTU)
    • Communications:
    • Warning / shutdown with common LED indication of shutdowns for:
    • 0 True RMS AC metering, 3-phase, +/-2% accuracy
    • Digital indication for:
    • Customizable screens
    • Failure to start (overcrank)
    • Serial annunciator module data link
    • Coolant temperature
    • Controls:
    • Overcurrent (50/51)
    • Number of I/O varies on options selected:
    • Reactive droop capability
    • Low coolant temperature
    • High coolant temperature
    • Min / max exciter
    • Alarm acknowledge
    • RPM
    • Generator phase sequence
    • Limiter and exciter diode monitor
    • Speed adjust
    • Operating hours
    • kW (per phase, average & percent
    • 3 Analog inputs
    • Generator mounted – rear facing
    • 6 Customer programmable digital inputs
  • Lubrication System
    • Oil filter, filler and dipstick
    • Oil drain lines and valve
    • Gear type lube oil pump
    • Fumes disposal
    • Lubricating oil
  • Mounting System
    • Rubber anti-vibration mounts (shipped loose)
    • Rails – engine/generator/radiator mounting
    • Anti-vibration mounts (shipped loose)
  • Starting System
    • 45 Amp charging alternator
    • 24 Volt electric starting motor
    • Battery and battery rack w/cables
    • Battery disconnect switch
  • Literature
    • English

Optional Equipment

  • Control System
    • EMCP 4.3, EMCP 4.4
  • Air Inlet System
    • Dual element air cleaner
    • Single element filter
  • Cooling System
    • Water level switch gauges
    • Optional installed ATAAC radiators
    • Standard ambient ATAAC radiators
    • Standard ambient radiators
    • Coolant
    • Optional installed radiators
  • Crankcase System
    • Explosion relief valves
    • No explosion relief valves
    • Ventilation system
  • Exhaust System
    • Elbows
    • Flange and exhaust expanders
    • Tier 4 clean emissions module
    • Tier 4 clean emission MOD Kits
    • Clean emission parts
    • Exhaust offset
    • Mufflers
    • Tier 4 dosing cabinet
    • Flanges
    • Flexible fittings
    • Y-Adapters
  • Fuel System
    • Fuel Priming Pumps (Tier 4) – Manual or Electric
    • Primary Fuel Filter
  • General
    • US aid emblem
    • Special paint (Colors other than Caterpillar yellow or high performance paints)
  • Generators and Attachments
    • Low / Medium voltage: 380/400/415 volts, 3 phase 1500 rpm. RW, IE, No. of Leads = 6, Pitch = .6667: 1600 Frame
    • Generator conversion
    • Differential current transformers (DCT)
    • Differential current transformers (DCT) 8.7 kV and 15 kV classes
    • Low / Medium voltage: 380, 440, 480, 600 volts, 3 phase 1800 rpm. RW, IE, No. of Leads = 6, Pitch = .6667: 1600 Frame
    • Low / Medium voltage: 380/400/415 volts, 3 phase 1500 rpm. RW, PM, No. of Leads = 6, Pitch = .6667: 1600 and 1800 Frames
    • Thermostat for space heater
    • Space heater
    • High voltage: 6300, 6600, 6900 volts, 3 phase 1800 rpm, FW, PM, No. of Leads = 6, Pitch = .6667: 2700, 3000 Frame
    • Alternator air cleaner
    • High voltage: 12470, 13200, 13800 volts, 3 phase 1800 rpm,FW, PM, No. of Leads = 6, Pitch = .6667: 2700, 3000 Frame
    • Low / Medium voltage: 380, 416, 440, 480, 600, 2400, 4160 Volts, 3 Phase 1800 RPM, FW, PM, No. of Leads = 6, Pitch = .6667: 1600, 1800 Frame
  • Instrumentation
    • Pyrometer and Thermocouples
  • Lubrication System
    • Oil level regulator
    • Prelube pumps
    • Lube oil in standard sump
  • Mounting System
    • Puck style low efficiency isolators
    • Spring type vibration isolators
    • IBC vibration isolators
  • Power Connections
    • Right side power connections
    • Ground cables between generator and terminal box
    • Neutral ground connections
    • Low voltage circuit breakers
    • 2700 Frame, four lead, four terminal
    • Rear power connections
    • Left side power connections
    • Center post busbar
  • Special Tests / Reports
    • PGS test report @ 0.8 power factor
    • PGS test report @ 1.0 power factor
    • Fuel consumption test
    • Canadian Standards Association certification
    • Torsional vibration analysis reports
    • IBC certification
    • generator test report
    • Generator set fuel consumption test
    • OSHPD certification
    • Standard engine test charge
  • Starting and Charging
    • Engine barring device
    • Air pressure regulator
    • Starter cover
    • Electric starting motors
    • Jacket water heaters
    • Air starting motors
    • 24 Volt battery set – Dry
    • 10, 20, 35 and 50 amp battery chargers
  • Extended Service Coverage
    • Platinum, Gold and Silver coverage

Enquiry Form

REQUEST A CALL BACK
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.